Detail publikace

Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems

ŠALPLACHTA, J. ZIKMUND, T. ZEMEK, M. BŘÍNEK, A. TAKEDA, Y. OMOTE, K. KAISER, J.

Originální název

Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure differentiates two types of ring artifacts according to their cause and character in computed tomography (CT) data. Each type is then addressed separately in the sinogram domain. The novel iterative schemes based on relative total variations (RTV) were integrated to detect the artifacts. The correction process uses the image inpainting, and the intensity deviations smoothing method. The procedure was implemented in scope of lab-based X-ray nano CT with detection systems based on charge-coupled device (CCD) and scientific complementary metal-oxide-semiconductor (sCMOS) technologies. The procedure was then further tested and optimized on the simulated data and the real CT data of selected samples with different compositions. The performance of the procedure was quantitatively evaluated in terms of the artifacts' detection accuracy, the comparison with existing methods, and the ability to preserve spatial resolution. The results show a high efficiency of ring removal and the preservation of the original sample's structure.

Klíčová slova

ring artifacts reduction; CCD detector; sCMOS detector; high-resolution X-ray computed tomography; relative total variation

Autoři

ŠALPLACHTA, J.; ZIKMUND, T.; ZEMEK, M.; BŘÍNEK, A.; TAKEDA, Y.; OMOTE, K.; KAISER, J.

Vydáno

1. 1. 2021

Nakladatel

MDPI

Místo

BASEL

ISSN

1424-8220

Periodikum

SENSORS

Ročník

21

Číslo

1

Stát

Švýcarská konfederace

Strany od

1

Strany do

20

Strany počet

20

URL

Plný text v Digitální knihovně

BibTex

@article{BUT168313,
  author="Jakub {Šalplachta} and Tomáš {Zikmund} and Marek {Zemek} and Adam {Břínek} and Yoshihiro {Takeda} and Kazuhiko {Omote} and Jozef {Kaiser}",
  title="Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems",
  journal="SENSORS",
  year="2021",
  volume="21",
  number="1",
  pages="1--20",
  doi="10.3390/s21010238",
  issn="1424-8220",
  url="https://www.mdpi.com/1424-8220/21/1/238"
}