Detail publikace
DETECTION OF THE RESPONSE PARAMETER CHANGE PRIOR TO AND AFTER THE APPLICATION OF BEESWAX COVER ON THE SURFACE OF CEMENT-MORTAR-MADE SPECIMENS
TREBULÁKOVÁ, P. CHROMÁ, M. CHOBOLA, Z.
Originální název
DETECTION OF THE RESPONSE PARAMETER CHANGE PRIOR TO AND AFTER THE APPLICATION OF BEESWAX COVER ON THE SURFACE OF CEMENT-MORTAR-MADE SPECIMENS
Anglický název
DETECTION OF THE RESPONSE PARAMETER CHANGE PRIOR TO AND AFTER THE APPLICATION OF BEESWAX COVER ON THE SURFACE OF CEMENT-MORTAR-MADE SPECIMENS
Jazyk
en
Originální abstrakt
The subject of this study consisted in detecting the change in the specimen response to an acoustic impulse produced by a hammer blow onto predefined points of cement-mortar specimen. The execution and evaluation of our experiments was based on the so-called Impact-echo method. The testing was carried out prior to and after the application of a protective beeswax cover to the test specimens. Thus obtained response signals were analyzed by means of the frequency inspection method.
Anglický abstrakt
The subject of this study consisted in detecting the change in the specimen response to an acoustic impulse produced by a hammer blow onto predefined points of cement-mortar specimen. The execution and evaluation of our experiments was based on the so-called Impact-echo method. The testing was carried out prior to and after the application of a protective beeswax cover to the test specimens. Thus obtained response signals were analyzed by means of the frequency inspection method.
Dokumenty
BibTex
@inproceedings{BUT25041,
author="Petra {Trebuláková} and Markéta {Rovnaníková} and Zdeněk {Chobola}",
title="DETECTION OF THE RESPONSE PARAMETER CHANGE PRIOR TO AND AFTER THE APPLICATION OF BEESWAX COVER ON THE SURFACE OF CEMENT-MORTAR-MADE SPECIMENS",
annote="The subject of this study consisted in detecting the change in the specimen response to an acoustic impulse produced by a hammer blow onto predefined points of cement-mortar specimen. The execution and evaluation of our experiments was based on the so-called Impact-echo method. The testing was carried out prior to and after the application of a protective beeswax cover to the test specimens. Thus obtained response signals were analyzed by means of the frequency inspection method.",
address="Brno University of Technology",
booktitle="Workshop NDT 2006",
chapter="25041",
institution="Brno University of Technology",
journal="Nezařazené články",
year="2006",
month="november",
pages="224--228",
publisher="Brno University of Technology",
type="conference paper"
}