Detail publikačního výsledku

Investigation of the non-linear variation in the photo-peak area of prompt gamma rays in NaCl aqueous solutions using the PGNAA technique

MEENA, D.; GUPTA, S.; CHEJARA, N.; BAWALIA, N.; DEGRA, S.; MALVIYA, R.; MEENA, R.; KATOVSKÝ, K.

Originální název

Investigation of the non-linear variation in the photo-peak area of prompt gamma rays in NaCl aqueous solutions using the PGNAA technique

Anglický název

Investigation of the non-linear variation in the photo-peak area of prompt gamma rays in NaCl aqueous solutions using the PGNAA technique

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

A Prompt Gamma-ray Neutron Activation Analysis (PGNAA) setup, comprising a radionuclide AmBe neutron source and an HPGe detector, was employed for the quantitative analysis of aqueous samples in University of Rajasthan laboratories. Various samples containing different amounts of sodium chloride (NaCl) solution, ranging from 10 to 1000 g, were dissolved in 5 liters of deionized water. For each sample, prompt gamma-ray data had been collected over a period of half an hour. The measurement outputs indicated that the prompt gamma-ray emission from chlorine did not increase linearly with NaCl concentrations above 100 g, due to neutron self-shielding effects. However, in the 10 to 100 g range, the counts showed an approximately linear dependence on concentration. Methodology for the minimum detectable concentration (MDC) of chlorine has been developed and adopted using the 6110.8 keV prompt gamma peak. The determined MDC of our setup was found to be 781 +/- 273 ppm in aqueous solution.

Anglický abstrakt

A Prompt Gamma-ray Neutron Activation Analysis (PGNAA) setup, comprising a radionuclide AmBe neutron source and an HPGe detector, was employed for the quantitative analysis of aqueous samples in University of Rajasthan laboratories. Various samples containing different amounts of sodium chloride (NaCl) solution, ranging from 10 to 1000 g, were dissolved in 5 liters of deionized water. For each sample, prompt gamma-ray data had been collected over a period of half an hour. The measurement outputs indicated that the prompt gamma-ray emission from chlorine did not increase linearly with NaCl concentrations above 100 g, due to neutron self-shielding effects. However, in the 10 to 100 g range, the counts showed an approximately linear dependence on concentration. Methodology for the minimum detectable concentration (MDC) of chlorine has been developed and adopted using the 6110.8 keV prompt gamma peak. The determined MDC of our setup was found to be 781 +/- 273 ppm in aqueous solution.

Klíčová slova

neutron activation; minimum detectable limit; high purity germanium detector; neutron self-shielding effect

Klíčová slova v angličtině

neutron activation; minimum detectable limit; high purity germanium detector; neutron self-shielding effect

Autoři

MEENA, D.; GUPTA, S.; CHEJARA, N.; BAWALIA, N.; DEGRA, S.; MALVIYA, R.; MEENA, R.; KATOVSKÝ, K.

Rok RIV

2026

Vydáno

01.01.2025

Nakladatel

IEEE

Místo

NEW YORK

ISBN

979-8-3315-8637-9

Kniha

International Scientific Conference on Electric Power Engineering

Periodikum

Proceedings of the ... International Scientific Conference on Electric Power Engineering

Stát

Spojené státy americké

Strany od

143

Strany do

146

Strany počet

4

BibTex

@inproceedings{BUT201328,
  author="{} and  {} and  {} and  {} and  {} and  {} and  {} and Karel {Katovský}",
  title="Investigation of the non-linear variation in the photo-peak area of prompt gamma rays in NaCl aqueous solutions using the PGNAA technique",
  booktitle="International Scientific Conference on Electric Power Engineering",
  year="2025",
  journal="Proceedings of the ... International Scientific Conference on Electric Power Engineering",
  pages="143--146",
  publisher="IEEE",
  address="NEW YORK",
  doi="10.1109/EPE67256.2025.11127148",
  isbn="979-8-3315-8637-9",
  issn="2376-5623"
}