Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
RICHTROVA, M.; KOSKOVA, O.; MARCIÁN, P.; BORÁK, L.; BONISCHOVA, T.; FABIAN, D.; JANKU, M.; JOUKAL, M.; VYMAZALOVA, K.; STOURAC, P.
Originální název
Customized protective palatal obturator for intubation in newborns in cleft lip surgery: a randomized controlled trial
Anglický název
Druh
Článek WoS
Originální abstrakt
BackgroundOrofacial clefts are common congenital malformations, affecting both facial aesthetics and function. Intubation in newborns with cleft lip and palate is challenging and carries a high risk of oral tissue damage. This study investigates the use of a customized protective palatal obturator (CPPO) to improve intubation safety and reduce tissue injury during cleft lip surgery.MethodsA single-center, randomized neonatal sub-study was conducted, including 55 newborns who underwent cleft lip surgery. Patients were randomized into an intervention group (CPPO use) and a control group (standard intubation without CPPO). The primary aim was to evaluate the degree of oral tissue injury during intubation, its severity, and location, in both groups, secondary aims included laryngoscopy image during intubation (modified Cormack-Lehane scoring system), intubation time, and attempts, number of intubations attempts and anesthesiologic complication during intubation. This study was registered on www.clinicaltrials.gov (ClinicalTrials.gov Identifier: NCT04422847 and NCT04422964).ResultsNo tissue damage occurred in the CPPO group, while the control group had a 21.4% incidence of tissue injury (p = .023). Secondary outcomes showed no statistically significant differences between groups for intubation time or the number of intubation attempts. Difficult intubation was less frequent in the CPPO group (40.7%) compared to the control group (50%), though this difference was not statistically significant.ConclusionThe CPPO significantly reduces the risk of tissue damage during intubation in newborns undergoing cleft lip surgery, without increasing intubation time or attempts. It is particularly beneficial for severe clefts, and its use may facilitate safer airway management in these high-risk patients.
Anglický abstrakt
Klíčová slova
Cleft lip, newborns, protective obturator, 3D printing, intubation, tissue damage, anesthesia management, patient specific approach
Klíčová slova v angličtině
Autoři
Rok RIV
2026
Vydáno
22.09.2025
Periodikum
ANNALS OF MEDICINE
Svazek
57
Číslo
1
Stát
Švédské království
Strany od
2561802
Strany počet
11
URL
https://www.tandfonline.com/doi/full/10.1080/07853890.2025.2561802
Plný text v Digitální knihovně
http://hdl.handle.net/11012/255580
BibTex
@article{BUT198893, author="{} and {} and {} and Petr {Marcián} and {} and Libor {Borák} and {} and {} and {} and {} and {} and {}", title="Customized protective palatal obturator for intubation in newborns in cleft lip surgery: a randomized controlled trial", journal="ANNALS OF MEDICINE", year="2025", volume="57", number="1", pages="11", doi="10.1080/07853890.2025.2561802", issn="0785-3890", url="https://www.tandfonline.com/doi/full/10.1080/07853890.2025.2561802" }