Hausdorff Distance for P wave Alignment in ECG with Intracardiac Validation

ŘEDINA, R.; LUCA, A.; HEJČ, J.; FILIPENSKÁ, M.

Originální název

Hausdorff Distance for P wave Alignment in ECG with Intracardiac Validation

Anglický název

Hausdorff Distance for P wave Alignment in ECG with Intracardiac Validation

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

The accurate alignment of P waves on surface electrocardiograms (ECG) is crucial to evaluating atrial electrical activity, particularly in patients with arrhythmias. This study introduces a novel P wave alignment method based on the Hausdorff distance, validated against intracardiac electrograms (EGM). The detection process incorporates a wavelet transform for QRS complex identification and dynamic pattern matching using the Hausdorff distance and Pearson’s correlation coefficient. Statistical analysis was performed using F and t tests to compare variances and mean shift values between the correlation and Hausdorff distance methods over various pattern durations. The results indicated that there were no significant differences between the two methods, apart from extreme cases (the p-values of the F test ranged from 0.003 to 0.265, and the pvalues of the t test ranged from 0.079 to 0.661). The findings suggest that both metrics perform similarly, offering reliable alternatives for the alignment of P waves in clinical and research applications. The proposed approach has the potential to enhance P wave detection, improving the precision of atrial signal analysis in patients with atrial arrhythmias.

Anglický abstrakt

The accurate alignment of P waves on surface electrocardiograms (ECG) is crucial to evaluating atrial electrical activity, particularly in patients with arrhythmias. This study introduces a novel P wave alignment method based on the Hausdorff distance, validated against intracardiac electrograms (EGM). The detection process incorporates a wavelet transform for QRS complex identification and dynamic pattern matching using the Hausdorff distance and Pearson’s correlation coefficient. Statistical analysis was performed using F and t tests to compare variances and mean shift values between the correlation and Hausdorff distance methods over various pattern durations. The results indicated that there were no significant differences between the two methods, apart from extreme cases (the p-values of the F test ranged from 0.003 to 0.265, and the pvalues of the t test ranged from 0.079 to 0.661). The findings suggest that both metrics perform similarly, offering reliable alternatives for the alignment of P waves in clinical and research applications. The proposed approach has the potential to enhance P wave detection, improving the precision of atrial signal analysis in patients with atrial arrhythmias.

Klíčová slova

Arrhythmia, Hausdorff distance, P wave alignment, Wavelet Transform, Intracardiac Electrograms

Klíčová slova v angličtině

Arrhythmia, Hausdorff distance, P wave alignment, Wavelet Transform, Intracardiac Electrograms

Autoři

ŘEDINA, R.; LUCA, A.; HEJČ, J.; FILIPENSKÁ, M.

Vydáno

29.04.2025

Nakladatel

Brno University of Technology, Faculty of Electrical Engineering and Communication

Místo

Brno

ISBN

978-80-214-6321-9

Kniha

PROCEEDINGS I OF THE 31ST STUDENT EEICT 2025

Edice

1st edition

Strany od

236

Strany do

240

Strany počet

5

URL

BibTex

@inproceedings{BUT198318,
  author="Richard {Ředina} and Adrain {Luca} and Jakub {Hejč} and Marina {Filipenská}",
  title="Hausdorff Distance for P wave Alignment in ECG with Intracardiac Validation",
  booktitle="PROCEEDINGS I OF THE 31ST STUDENT EEICT 2025",
  year="2025",
  series="1st edition",
  pages="236--240",
  publisher="Brno University of Technology, Faculty of Electrical Engineering     and Communication",
  address="Brno",
  isbn="978-80-214-6321-9",
  url="https://www.eeict.cz/eeict_download/archiv/sborniky/EEICT_2025_sbornik_1.pdf"
}