Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail aplikovaného výsledku
HOFMAN, J.; HÁZE, J.
Originální název
RadEx2 TID DEMO
Anglický název
Druh
Funkční vzorek
Abstrakt
RadEx2 is a second generation of Radiation Experiments developed to test effects of total ionizing dose (TID) on high resolution data acquisition systems for scientific space missions. It is highly miniaturized and therefore can be integrated with any nanosat platform like CubeSats. RadEx2 TID DEMO is a fully automated DAQ system designed to demonstrate and validate the design of RadEx2 during an in-situ TID experiment. It consists of the RadEx2 hardware placed in the irradiation facility, an external hardware generating the bus of the CubeSat, a high precision multimeter and a PC. The results of this experiment proved the designed features of the RadEx2, especially the superb quality of the core AD converter.
Abstrakt anglicky
Klíčová slova
AD converter, RADFET, voltage reference, dosimetry, CubeSat,TID
Klíčová slova anglicky
Umístění
168 Maxwell Avenue, Harwell, DIDCOT, Oxfordshire, OX 11 0QT, UK
Licenční poplatek
K využití výsledku jiným subjektem je vždy nutné nabytí licence
www
http://www.umel.feec.vutbr.cz/vyzkum/vysledky/funkcni-vzorky/