Challenges of infant pulmonary drug delivery: Aerosol deposition during realistic breathing

MIŠÍK, O.; PRINZ, F.; ELCNER, J.; LÁZŇOVSKÝ, J.; BĚLKA, M.; JUREN, T.; JEDELSKÝ, J.; LÍZAL, F.

Original Title

Challenges of infant pulmonary drug delivery: Aerosol deposition during realistic breathing

English Title

Challenges of infant pulmonary drug delivery: Aerosol deposition during realistic breathing

Type

WoS Article

Original Abstract

Effective inhalation therapy in infants presents significant challenges owing to their distinctive airway anatomy, respiratory patterns, and behavioural factors. This study examined aerosol deposition in a realistic infant airway model under various respiratory conditions, including normal breathing and crying. The airway geometry of a 10-month-old infant was reconstructed from computed tomography scans, and both computational (in silico) and experimental (in vitro) methodologies were employed to analyse aerosol deposition patterns. The findings demonstrated that while a substantial proportion of nebulised aerosol particles (70%) bypassed the upper respiratory tract during stationary inspiration, realistic breathing patterns revealed considerable variations in deposition. Notably, crying significantly increased aerosol deposition in the upper airways. Particle size also exhibited a crucial role, with 5 & micro;m particles demonstrating 50% deposition in the upper airways during normal breathing compared to only 6% for 2.5 & micro;m particles. This observation underscores the suboptimal nature of current inhalation products, which are frequently designed for particle sizes of 1-5 & micro;m. This study provides valuable insights into aerosol delivery in infants, emphasising the need for age-specific inhalation therapy. Modifications in particle size distribution, potentially towards smaller particles (1-2.5 & micro;m), may enhance therapeutic outcomes. Further research is warranted to develop infant-specific airway models and to explore alternative particle designs to optimise inhalation drug delivery in this vulnerable population.

English abstract

Effective inhalation therapy in infants presents significant challenges owing to their distinctive airway anatomy, respiratory patterns, and behavioural factors. This study examined aerosol deposition in a realistic infant airway model under various respiratory conditions, including normal breathing and crying. The airway geometry of a 10-month-old infant was reconstructed from computed tomography scans, and both computational (in silico) and experimental (in vitro) methodologies were employed to analyse aerosol deposition patterns. The findings demonstrated that while a substantial proportion of nebulised aerosol particles (70%) bypassed the upper respiratory tract during stationary inspiration, realistic breathing patterns revealed considerable variations in deposition. Notably, crying significantly increased aerosol deposition in the upper airways. Particle size also exhibited a crucial role, with 5 & micro;m particles demonstrating 50% deposition in the upper airways during normal breathing compared to only 6% for 2.5 & micro;m particles. This observation underscores the suboptimal nature of current inhalation products, which are frequently designed for particle sizes of 1-5 & micro;m. This study provides valuable insights into aerosol delivery in infants, emphasising the need for age-specific inhalation therapy. Modifications in particle size distribution, potentially towards smaller particles (1-2.5 & micro;m), may enhance therapeutic outcomes. Further research is warranted to develop infant-specific airway models and to explore alternative particle designs to optimise inhalation drug delivery in this vulnerable population.

Keywords

infant, airways, inhalation, aerosol deposition, computational fluid dynamics

Key words in English

infant, airways, inhalation, aerosol deposition, computational fluid dynamics

Authors

MIŠÍK, O.; PRINZ, F.; ELCNER, J.; LÁZŇOVSKÝ, J.; BĚLKA, M.; JUREN, T.; JEDELSKÝ, J.; LÍZAL, F.

Released

12.05.2026

Publisher

Springer Nature

Periodical

Experimental and Computational Multiphase Flow

Volume

8

Number

2

State

People's Republic of China

Pages from

262

Pages to

275

Pages count

14

URL

Full text in the Digital Library

BibTex

@article{BUT202027,
  author="Ondrej {Mišík} and František {Prinz} and Jakub {Elcner} and Jakub {Lázňovský} and Miloslav {Bělka} and  {} and Jan {Jedelský} and František {Lízal}",
  title="Challenges of infant pulmonary drug delivery: Aerosol deposition during realistic breathing",
  journal="Experimental and Computational Multiphase Flow",
  year="2026",
  volume="8",
  number="2",
  pages="262--275",
  doi="10.1007/s42757-025-0266-x",
  issn="2661-8869",
  url="https://link.springer.com/article/10.1007/s42757-025-0266-x"
}