Publication result detail

Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes

POBUCKÁ, S.; KUČÍREK, P.; ŠUHAJDA, K.; HOLEŠOVSKÝ, J.

Original Title

Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes

English Title

Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes

Type

WoS Article

Original Abstract

This study is focused on the analysis of the crawl space microclimate in timber structures in the Czech Republic. It focused on the conditions in which the timber and fiberboard elements of the crawl space ceiling structure are located. As part of the analysis, air temperature, relative humidity, air flow within the crawl space were monitored. The average relative humidity within the crawl space reached up to 85% in summer and up to 90% in winter. The residence time of air in the crawl space was determined using air age simulation. A long residence time of air in the crawl space may pose a risk of capturing mold spores on the crawl space wall and ceiling surfaces. OpenFOAM software was used for the simulations. The analysis revealed the presence of fungal spores of the genera Penicillium, Aspergillus, and Cladosporium.

English abstract

This study is focused on the analysis of the crawl space microclimate in timber structures in the Czech Republic. It focused on the conditions in which the timber and fiberboard elements of the crawl space ceiling structure are located. As part of the analysis, air temperature, relative humidity, air flow within the crawl space were monitored. The average relative humidity within the crawl space reached up to 85% in summer and up to 90% in winter. The residence time of air in the crawl space was determined using air age simulation. A long residence time of air in the crawl space may pose a risk of capturing mold spores on the crawl space wall and ceiling surfaces. OpenFOAM software was used for the simulations. The analysis revealed the presence of fungal spores of the genera Penicillium, Aspergillus, and Cladosporium.

Keywords

foundation of timber structures; age simulation; heat and moisture transfer

Key words in English

foundation of timber structures; age simulation; heat and moisture transfer

Authors

POBUCKÁ, S.; KUČÍREK, P.; ŠUHAJDA, K.; HOLEŠOVSKÝ, J.

Released

10.04.2025

Periodical

Acta Facultatis Xylologiae Zvolen

Volume

67

Number

1

State

Slovak Republic

Pages from

109

Pages to

124

Pages count

16

URL

BibTex

@article{BUT199488,
  author="Slávka {Pobucká} and Pavel {Kučírek} and Karel {Šuhajda} and Jan {Holešovský}",
  title="Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes",
  journal="Acta Facultatis Xylologiae Zvolen",
  year="2025",
  volume="67",
  number="1",
  pages="109--124",
  doi="10.17423/afx.2025.67.1.10",
  issn="1336-3824",
  url="https://df.tuzvo.sk/sites/default/files/10-01-25_0_0.pdf"
}